Active Harmonic Filter (AHF)
High Quality Harmonic Control Scheme
Read more
- 2nd to 50th harmonic mitigation
- Real-time compensation
- Modular design
- Protect equipement from being over heated or failure
- Improve working efficiency of equipment
-
Excellent filtering performance
-
Modular design
-
Multiple compensation modes
-
Use high-end components
-
Safe and reliable
Active Harmonic Filter (AHF) An active harmonic filter is a type of electronic device that is used to mitigate or eliminate harmonic distortions in electrical power systems. Harmonic distortion refers to the presence of unwanted frequencies in the power system that can lead to issues such as increased heating of equipment, reduced system efficiency, and even equipment failure.
AHF operates by sensing the harmonic currents in the system and generating a counter-current of the same magnitude and opposite phase. This counter-current cancels out the harmonic current and prevents it from being fed back into the power system. Active harmonic filters are designed to be fast and accurate in their response to changing harmonic conditions in the power system.Active harmonic filters are commonly used in industrial and commercial settings where there are high levels of non linear loads, such as variable frequency drives, uninterruptible power supplies, and computer equipment. They are also used in power quality improvement applications in residential and commercial buildings.

Active Harmonic Filter (AHF)
With the load current detected by external CT, DSP as CPU has advanced logic control arithmetic, could quickly track the instruction current, divide the load current into active power and reactive power by using the intelligent FFT, and calculate the harmonic content rapidly and accurately. Then it sends PWM signal to internal IGBT's driver board to control IGBT on and off at 20KHZ frequency. Finally, it generates opposite phase compensation current on inverter induction. In the meanwhile, CT also detects the output current and negative feedback goes to DSP. Then DSP proceeds the next logical control to achieve more accurate and stable system.
Application Field
010203
Type:single phase 220V Series,three phase 400V / 220V Series,500V Series,690V Series
Network:Single phase / 3 phase 3 wire / 3 phase 4 wire
Rated frequency:50Hz/60Hz
Response time:<40ms
Harmonic compensation rate:>92%
Harmonics filtering:2nd to 50th Harmonics,The number of compensation can be selected, and the range of single compensation can be adjusted
Rated compensation current:23A~500A