APQ Series Modify Sine Wave Inverter & Charger
The APQ modified sine wave inverter/charger shall utilize line-interactive topology. It consists of an auto transformer, battery charger, battery, inverter, transfer switches and all associated controls, monitoring and major protection devices. It shall denote the hardware and firmware associated to provide high quality AC power for sensitive electronic and other critical loads. In the event of utility abnormalities (sags and swells), the AC output power shall be corrected by means of boost (sag correction) or buck (swell correction) compensation taps. Operation of the compensation taps shall be seamless and automatically maintain the proper output voltage for the connected critical equipment. The compensation taps shall be designed for indefinite operation at full rated load to their voltage limits, without discharging the battery.
● Low Frequency design, Modified sine wave output
● off mode charging
● Full automatic and silent operation
● Built-in 20Amp super charger for up to 100Ah battery
● Three-steps intelligent charging control to recharging time
● informative LED indicator and alarms
● Different AC outlet configurations available: NEMA, Schuko, French ,India
● Small scale and cost effective for home appliances and office equipment
APQ Specification | |||
Inverter output | Model | 600W | 1000W |
Continuous Output Power | 600W | 1000W | |
Surge Rating(20s) | 1800W | 3000W | |
Putput Waveform | Modified Sine Wave/Same as input(Bypass mode) | ||
Nominal Efficiency | 80%(Peak) | ||
Line Mode Efficiency | >95% | ||
Power Factor | 0.9-1.0 | ||
Nominal Output Voltage rms | 110V/120V/220V/230V/240VAC | ||
Output Voltage regulation | ±10%rms | ||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||
Short Circuit Protection | Yes(1s after fault) | ||
Typical transfer Time | 10ms(Max) | ||
DC Input | Nominal Input Voltage | 12V | 24V |
Minimum Start Voltage | 10V | 20V | |
Low Battery Alarm | 10.5V | 21V | |
Low Battery Trip | 10V | 20V | |
High Voltage Alarm | 16V | 32V | |
Low Battery voltage recover | 13V | 26V | |
Charge | Input voltage Range | 75/90-150VAC | 115/148-290VAC |
Output Voltage | ±10%rms | ||
Charger Breaker Rating | 10A | 20A | |
Max Charge Rate | 30A/15A | ||
Battery Initial Voltage for Start | 0-15.7V for 12V(*2 for 24V) | ||
Over Charge Protection Shutdown | 15.7V for 12V(*2 for 24V) | ||
Charger curve (4 stage constant current)Battery types 4 step digital controlled progressive charge | |||
Bypass & Protection | Input Voltage Waveform | Sine wave(Grid or Generator) | |
Nominal Voltage | 110VAC/120VAC | 230VAC | |
Low Voltage Trip | 75/90V±4% | 115/148V±4% | |
Low Voltage re engage | 85V/100V±4% | 125V/158V±4% | |
High Voltage Trip | 150V±4% | 290V±4% | |
High Voltage re engage | 140V±4% | 280V±4% | |
Max Input AC Voltage | 170VAC | 300VAC | |
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | ||
Low Freq Trip | 45±0.3Hz for 50Hz,55±0.3Hz for 60Hz | ||
Low Freq re engage | 47±0.3Hz for 50Hz,57±0.3Hz for 60Hz | ||
High Freq Trip | 55±0.3Hz for 50Hz,65±0.3Hz for 60Hz | ||
High Freq re engage | 54±0.3Hz for 50Hz,64±0.3Hz for 60Hz | ||
Overload protection(SMPS load) | Circuit breaker& Software Protection | ||
Output Short circuit protection | Circuit breaker& Software Protection | ||
Bypass breaker rating | 10A | 20A | |
MechanicalSpecifications | |||
Mounting | Wall mount | ||
Inverter Dimensions(L*W*H) | 285×145×145mm | ||
Inverter Weight | 12KG | 16KG | |
Shipping Dimensions(L*W*H) | 385×245×245mm | ||
Shipping Weight | 14KG | 18KG | |
Display | Status LEDs | ||
Standard | 1 Year |