T/EX Series High Frequency Online UPS
Application:
T/EX Series 6KVA~20KVA High frequency online UPS is specially designed for servers,data-center critical network devices,sensitive electronic equipment,telecom,bank,hospital,bureau,traffic,public security,Army and so on.
FEATURES:
l Large Blue Ground LCD digital display shows Detailed Real-Time UPS Status and parameters.
l Output Voltage,Frequency parameter and bypass function can be set via the display.
l Advanced MCU microprocessor control technology and DSP technology,ensure long life reliability.
l Wide input voltage range,Zero transfer time.
l True online double conversion technology.
l N+X Parallel Rseundancy.
l Excellent Protection against over voltage,over load,over current,over charge and so on.
l Input L and N lines reverse wiring detection,Auto start when AC back.
l DC start function,Input PFC revise function.
l Humanization bypass output,can be adjustable.
l Smart RS232 communication with monitoring software.
l Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
l Available to work with generators.
l Lightning,surge,short circuit,Network/fax/modem surge protection.
SPECIFICATIONS:
LCD MODEL | EX6K | EX10K | EX6KL | EX10KL | EX3110K | EX3110KL | EX3115KL | EX3120KL | |
LED MODEL | T6K | T10K | T6KL | T10KL | T3110K | T3110KL | T3115KL | T3120KL | |
CAPACITY | VA/W | 6KVA4.2KW | 10KVA7KW | 6KVA4.2KW | 10KVA7KW | 10KVA7KW | 10KVA7KW | 15KVA10.5KW | 20KVA14KW |
INPUT |
Nominal Voltage |
220/230/240VAC |
380VAC |
||||||
Voltage Range |
176-276VAC |
304-478VAC |
|||||||
Frequency Range |
50Hz:46~54Hz;60Hz:56~64Hz |
||||||||
Phase |
Single phase with Ground |
Three phase (4 Wires+Ground) |
|||||||
Power Factor |
>=0.97 |
>=0.95 |
|||||||
OUTPUT |
Voltage |
220/230/240*(1±1%)VAC |
|||||||
Frequency |
50/60Hz(Adjustable) 50Hz AC Mode:Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz(1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range 56~64Hz); Battery Mode:60Hz(1±0.2%) |
||||||||
Wave Form |
Pure Sine Wave |
||||||||
Power Factor |
0.7/0.8 |
||||||||
Harmonic Distortion |
=<2% THD (Linear Load),=<6% THD (Non-Linear Load) |
||||||||
Overload Capacity |
105%-130% for 10 min,130% for 1 min |
||||||||
Current Crest Ratio |
3:1 |
||||||||
Connections |
Terminal block |
||||||||
Efficiency |
To AC Mode |
88% |
85% |
||||||
To Battery Mode |
87% |
||||||||
Battery |
Type |
Sealed free maintenance lead acid battery |
|||||||
Nominal DC voltage | Built in batteries 12v7.2ah*20pcs |
240VDC |
12v7.2ah |
240VDC |
|||||
Quantity | 20pcs | 20pcs | Depends on requested back-up time | 20pcs |
Depends on requested back-up time |
||||
Back-up Time (Full load) |
>=7 minutes |
>=5 minutes |
Depends on the capacity of external battery bank |
>=5 minutes 5minutes |
Depends on the capacityof external battery bank | ||||
Recharge Time |
7 hours to 90% |
Depends on the capacity of external battery bank | 7 hours to 90% | Depends on the capacity of external battery bank | |||||
Charge current(MAX) |
2.0A |
4.2A or 8A |
2.0A |
4.2A or 8A |
|||||
Charge voltage |
274Vdc±1%V |
||||||||
Bypass |
Automatic Transfer |
On overload and UPS failure |
|||||||
Before UPS Power-on |
Default “ON” user adjustable to “YES” |
||||||||
Transfer Time |
Zero |
||||||||
Indicators | LED/LCD Display |
UPS status,I/P & O/P voltage&frequency,Battery voltage,Battery capacity,Loading,Fault code |
|||||||
Audible Alarm |
Bypass,On battery mode,Battery low,Overload,Fault |
||||||||
Acoustic noise | At 1 meter distance |
<55dB |
<60dB |
||||||
Communications |
Intelligent RS232 serial port | Windows 98/NT/2000/XP/2003,Linux,Sun Solaris,IBM Aix,Compaq True64,SGI IRIX,FreeBSD,HP-UX,and MAC | |||||||
SNMP(Optional) | Power management from SNMP manager and web browser | ||||||||
USB(Optional) | Windows family software and Mac OS | ||||||||
Environmental | Operating Temperature |
0~40℃ |
|||||||
Operating Humidity |
20~90%(Non Condensing) |
||||||||
Weight | Net weight |
84 |
93 |
35 |
38 |
88.5 |
39.5 |
58 |
58 |
UPS Dimension | L*W*H(mm) |
570*260*717 |
*LED/LCD display panel optional