Industry UPS G-HT Series 3:3 Phase 10-200KVA
Application:
Larger-medium computer data center,industrial process and other mission-critical equipment
High reliability
True on-line static bypass technology, to provide strong overload and fault protection device.
Internal manual maintenance bypass, further improve the reliability of continuous operation of the load.
Net work management humanity
Communicate with PC by Rs232
Use SNMP adapter, UPS can realize remote network management function.
Optimized battery performance
Intelligent battery management function(ABM)
Automatically convert to constant-current constant-voltage charging technology.
Parallel redundancy
- Can parallel 8 units UPS
- Parallel UPS units can share a battery pack;
- Non-fixed master/slave parallel
Industry UPS G-HT Series
Model |
10KS | 20KS | 30KS | 40KS | 60KS | 80KS | 100KS | 120KS | 160KS | 200KS | ||||||||||
Rated Power |
10KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | ||||||||||
(VAM) | 8KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW | ||||||||||
Input | ||||||||||||||||||||
Input voltage |
380VAC(3 phase)or 190VAC(3 phase) |
|||||||||||||||||||
Voltage Range |
304~456VAC or 152-228VAC |
|||||||||||||||||||
Frequency |
50/60Hz±5% |
|||||||||||||||||||
Power Factor |
>0.97 |
|||||||||||||||||||
Max Input Current | 18A | 37A | 55A | 72A | 108A | 130A | 160A | 190A | 245A | 310A | ||||||||||
Output | ||||||||||||||||||||
Voltage |
380VAC/190VAC±1% |
|||||||||||||||||||
Frequency |
Sync to input(line mode),50Hz or 60Hz±0.05 |
|||||||||||||||||||
Waveform Type |
Pure sine wave |
|||||||||||||||||||
Power Factor |
0.8 |
|||||||||||||||||||
THD |
<3% with linear load 110% for |
|||||||||||||||||||
Overload Capability |
300mins/125% for 10mins/150% for 1 min then transfer to bypass&alarm |
|||||||||||||||||||
Current Crest Ratio |
3:1(max) |
|||||||||||||||||||
Overall efficiency |
>90% |
|||||||||||||||||||
Transfer Time | ||||||||||||||||||||
From inverter to battery |
0ms |
|||||||||||||||||||
Bypass | ||||||||||||||||||||
Voltage |
380VAC |
|||||||||||||||||||
Bypass voltage range |
±10%,±15%,±20%adjustable |
|||||||||||||||||||
Battery | ||||||||||||||||||||
voltage |
384VDC |
432VDC |
480VDC |
|||||||||||||||||
Recharge |
8~0hrs to 90% of capacity after full load discharge |
|||||||||||||||||||
LED/LCD Indications | ||||||||||||||||||||
LED |
Battery level,utility power |
|||||||||||||||||||
LCD |
Input/output voltage,Frequency,battery voltage,load percent,Temperature |
|||||||||||||||||||
Communications | ||||||||||||||||||||
interface |
Rs 232 SNMP(optional) |
|||||||||||||||||||
intelligent |
Dry contact/EPO/SNMP Card(optional) |
|||||||||||||||||||
Working condition | ||||||||||||||||||||
Temperature |
0~40℃ |
|||||||||||||||||||
Humidity |
0-95%℃ non-condensing |
|||||||||||||||||||
Storage Temperature |
-25℃~55%℃ |
|||||||||||||||||||
Acoustic Noise |
<55dB |
<60dB |
<65dB |
<70dB |
||||||||||||||||
Weight | ||||||||||||||||||||
N.W(Kg) |
223 |
260 |
336 |
351 |
497 |
556 |
756 |
901 |
1300 |
1350 |
||||||||||
G.W(Kg) |
280 |
317 |
393 |
408 |
574 |
633 |
856 |
1001 |
1400 |
1450 |
||||||||||
WxDxH mm |
555*725*1220 |
800*745*1400 |
1070*745*1400 |
1420*745*1810 |