Leave Your Message
您的浏览器版本不支持canvas
30.72Kwh Energy Storage System LiFePO4 battery pack
LiFePO4 Battery Pack

30.72Kwh Energy Storage System LiFePO4 battery pack

Short Description:

 

HOME ENERGY STORAGE SYSTEM

ALL-IN-ONE
12KW / 30.72KWH

ESS12048E600P4

 

Built with YIY off grid inverter charger
CAN / RS485 / WIFI APP
Multi working modes selectable
Modular design, flexible installation

 

INVERTER : HP 12048DR  48V / 12KW
BATTERY : LFP 48200R*3 51.2V / 200AH
MPPT : SCM 48240R 240A / 48V
SOLAR PANELS : 370M6H  370W*36PCS

    SYSTEM BREAKDOWN STRUCTURE

    ESS-30KWH 2
     

    TECHNICAL PARAMETERS

    Model Configuration
    ESS12048E600P4 MPPT-SCM 48240R INVERTER-HP 12048DR BATTERY-LFP 48200R*3 Total energy
    240A(60A*4) 12KW 600AH(200AH*3) 30.72kwh
         
    Battery Description
    Normal specification
    1 Rated Voltage 51.2V
    2 Rated Capacity 600Ah
    3 Rated Energy 30.72KWH
    4 Battery Configuration 10.24KWH(16S2P) *3PCS
    5 Battery Cell 3.2V100AH 96PCS
    Standard Charge
    1 Operation temperature range @charging 0~45℃
    2 Rated charge voltage 55.2±0.4V
    3 Max charge voltage 56.8±0.4V
    4 Overcharge protection 58.4±0.4V
    5 Allowed MAX charge current(Total) 330A withstand 30s (every pack 110A)
    6 Peak charge current(Total) 360A withstand 5s (every pack 120A)
    7 Rated charge current(Total) 300A (every pack 100A)
    8 Recommend charge current(Total) <300A
    Standard discharge
    1 Operation temperature range @discharging -20~60℃
    2 Output Voltage Range 40~56Vdc
    3 Recommend Working Range 46~54Vdc
    4 Discharge Cut-off voltage 40V
    5 Allowed MAX discharge current(Total) 660A withstand 30s (every pack 220A)
    6 Peak discharge current(Total) 720A withstand 5s (every pack 240A)
    7 Rated discharge current(Total) 600A (every pack 200A)
    8 Recommend discharge current(Total) <600A
    Communication
    1 RS485 For LCD remote
    2 CAN PC control and monitor
    Inverter (built-in) Description
    Normal specification
    1 Rated Power 12KW
    2 Output Waveform Pure Sine Wave/Same as input (Bypass Mode)
    3 Output Voltage 240Vac(H-H)/120Vac(H-N) ±10% RMS
    4 Output Frequency 50 or 60± 0.3Hz (Inverter mode by sw4 setting)
    5 Typical Transfer Time 4-6ms typical,10ms(Max)
    6 THD < 3%(Rated voltage full R load)
    7 AC Input Range 184-253Vac (UPS mode) or 140-270Vac (GEN mode)
    8 Customized AC Charger Battery type selector position 9, special design for LFP, make the battery cycle life Maximization
    9 MAX AC Charge Current 100A
    10 Battery priority Function Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc
    11 AC Bypass without charging Battery type selector position 0
    MPPT (built-in) Description
    Normal specification
    1 PV POWER 3.5KW*4
    2 PV Input Voltage 60-145Vdc
    3 MPPT Charging Voltage 56.0Vdc (Fast charging)/54Vdc (Float charging)
    4 MPPT Output Current 60A*4
    Mechanical Characteristics
    ESS12048E600P4 Dimension H*W*D Shipping H*W*D Weight(N.W.) Weight(G.W.)
    1360*560*960mm 1540*700*1050mm 440KG 480KG
     

    APPLICATION

    application
     


    description2