    HTB10QAlIVXXXXaoXXXXq6xXFXXX71Adopts New Pure Sine-wave Inverter Technology2High power density with superior reliability and performance3Surge Rating: 2 * Prated4Input/output isolated design5Design for harsh environment and various equipments6“All master” dynamic mechanism eliminate single point failure to optimize reliability7Pure sine wave output (THD < 3%)8Output frequency: 50 / 60Hz switch selectable9Low power “Power Saving Mode” to conserve energy10Capable of driving highly reactive & capacitive loads at start moment.11LED indicators display12Advanced DSP Control13Protection: Input low voltage/Overload/Short circuit/Low battery alarm/Input over voltage/Over temperature/ High output voltage/Low output voltage/Unit internal failure/Unit parallel failure14N+X redundancy function (optional)15Adopting DIP (Dual ln-line Package) switch

    Slide to the left for full table
    Specification Model No.
    Item OPS0612 OPS1012 OPS2012 OPS0612E OPS1012E OPS2012E OPS3012E
    Input
    Nominal voltage 12Vdc(*2 for 24Vdc)
    Operating range 10Vdc ~ 15Vdc
    Startup voltage 11.75Vdc~14.7Vdc
      Load level 0~29% 30~69% 70~100%
    Battery alarmlevel battery-low level 11.3Vdc 11.2Vdc 11.0Vdc
    battery-high level 14.0Vdc 13.9Vdc 13.7Vdc
    Battery shut-down level battery-under level 10.3Vdc 10.2Vdc 10.0Vdc
    battery-over level 15.0Vdc 14.9Vdc 14.7Vdc
    Battery recovery level battery-under recovery 12.5Vdc
    battery-over recovery 14.0Vdc
    Output
    Output Waveform Pure sine wave
    Output Power 600W 1000W 2000W 600W 1000W 2000W 3000W
    Surge Rating 2 * Prated
    Nominal Output Voltage 110 / 115 / 120Vac 220 / 230 / 240Vac
    Output Voltage Regulation ± 5%……when input voltage higher than battery-low level
    Output Frequency 50/60Hz ± 0.1%
    Output Current @ 220/230/240 2.73A / 2.61A / 2.50A 4.55A / 4.35A / 4.17A 9.10A / 8.70A / 8.34A 13.65A / 13.05A / 12.51A
    Output Current @ 110/115/120 5.45A / 5.22A / 5A 9.09A / 8.70A / 8.33A 18.18A / 17.39A / 16.67A
    Crest factor 03:01
    THD <3%, linear load; <5%, non-linear load….at nominal input voltage
    <15%………………………………………………….at minimum cut-off (10Vdc) level
    Note: non-linear load condition: P.F.>0.7
    Peak Output Current @ 220/230/240 5.46A / 5.22A / 5.00A 9.10A /8.70A / 8.34A 18.20A / 17.40A / 16.68A 27.3A / 26.1A / 25.02A
    Peak Output Current @ 110/115/120 10.92A / 10.44A / 10A 18.2A / 17.4A / 16.68A 27.3A / 26.1A / 25A 36.4A / 34.8A / 33.36A
    Efficiency >88% (typical), 90% (peak) >90% (typical), 92% (peak)
    No load Current Draw <12W <20W <12W <20W
    Stand-by Current Draw <6W <10W <6W <10W
    Over load protection Refer to Sec.3.9 and Sec.3.10
    Environmental
    Noise <50 dB
    Operating temperature Operation temperature: –20 to +70°C
    –5 to +40 °C with full performance.
    Storage temperature -30 ~ 70°C
    Operating humidity 90% RH (no condense)
    Operating Attitude 1500m
    Safety EN60950, UL-458, CE
    EMC FCC Part 15 class B, EN55022 Class B, e-mark
    Mechanical
    Dimension L x W x H (mm) 270*160*70 355*180*82 412*285*121 270*160*70 355*180*82 412*285*121 412*285*121
    Weight (Kg) 2.5 4.0 8.0 1.5 4.0 8.0 10.0
    Force cooling Load and Temperature Controlled Cooling Fan
    Control
    Protection Overload, Short circuits, Reverse polarity, Over / under input voltage, Over temperature, High output voltage, Low output voltage, Unit internal failure, Unit in-parallel failure
    Startup time < 5 Seconds
    Power Saving Recovery Time 5 Seconds
    Human Interface
    LED Indicator 3-LED installed
    Audible Alarm Buzzer
    Communication Interface RS232

    HTB1Sqr5IVXXXXaPaXXXq6xXFXXXw

    HTB1dPgXIVXXXXbTXVXXq6xXFXXXyHTB1ydEqIVXXXXXDXXXXq6xXFXXXqHTB1cPUXIVXXXXbnXVXXq6xXFXXXp