4th Gen HP Series Inverter with Charger 1-15KW

low frequency inverter 110/220Vac Split Phase output 3x surge capability AC/Battery Priority Selector Multi Stage Smart charger 150 Amp remote LCD panel available 10msec typical transfer time optional 25W power save mode 8 battery charger settings

HT1tQR3FThbXXagOFbXW
HP Series Pure Sine Wave Inverter & MPPT & Charger
HP-PV Series Pure Sine Wave Inverter is a combination of an inverter, charger, solar power and Auto-transfer switch into one complete system . It is packed with unique features and it is one of the most advanced inverter/chargers in the market today.

Feature of HP Series Inverter & MPPT & Charger

    v Smart Remote Control (RMT)
    v Battery Temperature Sensor (BTS)
    v Automatic Generator Starting (AGS)
    v Support Solar Panel with MPPT Function
    v Designed to Operate under Harsh Environment
    v DC Start & Automatic Self-Diagnostic Function
    v Compatible with Both Linear & Non-Linear Load
    v Easy to Install & Easy to Operate & Easy to Solve
    v Low DC Voltage Supports Home & Office Appliances
    v Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%
    v High Efficiency Design & “Power Saving Mode” to Conserve Energy
    v Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration
    v 13 Vdc Battery Recover Point, Dedicated for Renewable Energy Systems
    v 8 pre Set Battery Type Selector plus De-sulphation for Totally Flat Batteries
    v 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger
    v 8 ms Typical Transfer Time Between Utility & Battery, Guarantees Power Continuity
    v 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator

 

Slide to the left for full table
Electrical Specifications
Inverter Output Model 1KW 1.5 KW 2KW 3.KW 4KW 5KW 6KW 8KW 10KW 12KW 15KW
kContinuous Output Power 1KW 1.5 KW 2KW 3KW 4KW 5KW 6KW 8KW 10KW 12KW 15KW
Surge Rating (20Secs) 3KW 4.5 KW 6KW 9KW 12KW 15KW 18KW 24KW 30KW 36KW 45KW
Output Waveform Pure Sine wave/Same as input(Bypass Mode)
Nominal Efficiency >88%(Peak)
Line Mode Efficiency >95%
Power Factor 0.9-1.0
Nominal Output Voltage rms 100-110-120Vac / 220-230-240Vac
Output Voltage Regulation ±10% RMS
Output Frequency 50Hz ± 0.3Hz/60Hz ± 0.3Hz
Short Circuit Protection Yes( 1sec after fault )
Typical transfer Time 10ms(Max)
THD < 10%
DC Input Nominal Input Voltage 12.0Vdc/24.0Vdc/48.0Vdc 24.0Vdc/ 48.0Vdc 48.0Vdc
Minimum Start Voltage 10.0Vdc/ 10.5Vdc for 12Vdc Mode  *2 for 24Vdc,  *4 for 48Vdc ;
Low Battery Alarm 10.5Vdc/ 11.0Vdc for 12Vdc Mode
Low Battery Trip 10.0Vdc/ 10.5Vdc for 12Vdc Mode
High Voltage Alarm 16.0Vdc for 12Vdc Mode
Low Battery Voltage Recover 15.5Vdc for 12Vdc Mode
Idle Consumption-Search Mode < 25 W when Power Saver On.
Charger Output Voltage Depends on battery type
Charger Breaker Rating 20A 20A 20A 25A 32A 40A 40A 50A 80A 80A 80A
Max Charge  Power Rate 1/3 Rating Power
Battery Initial Voltage for Start 10-15.7Vdc for 12Vdc Mode *2 for 24Vdc,  *4 for 48Vdc ;
Over Charge Protection Shutdown 15.7Vdc for 12Vdc Mode
BTS Battery Temperature Sensor (Optional)  Yes

Variances in Charging Voltage & S.D Voltage Based on the Battery Temperature.

 

Bypass & Protection Input Voltage Waveform Sine wave (Grid or Generator)
Nominal Voltage 100-110-120Vac / 220-230-240Vac
Max Input AC Voltage 150VAC For 120Vac LV Mode;  300VAC For 230Vac HV Mode;
Nominal Input Frequency 50Hz or 60Hz (Auto detect)
Low Freq Trip 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
High Freq Trip 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
Overload protection (SMPS load) Circuit Breaker
Output Short circuit protection Circuit Breaker
Bypass Breaker Rating 20A 20A 20A 25A 32A 40A 40A 50A 80A 80A 80A
Transfer switch Rating 30Amp for UL & TUV 40Amp for UL 80Amp for UL
Bypass Without Battery Connected Yes (Optional)
Max Bypass Current 30Amp 40Amp 80Amp
Solar Charger (Optional) Rated Voltage 12Vdc / 24Vdc / 48Vdc
Solar Input Voltage Range 15-45Vdc / 30-70Vdc / 60-100Vdc
Rated Charge Current 40 or 60A
Rated Output Current 15A
Self Consumption < 10mA
Bulk Charge (Default) 14.5Vdc for 12Vdc Mode *2 for 24Vdc, *4 for 48Vdc
Floating Charge(Default) 13.5Vdc for 12Vdc Mode
Equalization Charge(Default) 14.0Vdc for 12Vdc Mode
Over Charge Disconnection 14.8Vdc for 12Vdc Mode
Over Charge Recovery 13.6Vdc for 12Vdc Mode
Over Discharge Disconnection 10.8Vdc for 12Vdc Mode
Over Discharge Reconnection 12.3Vdc for 12Vdc Mode
Temperature Compensation   -13.2mV/°C for 12Vdc Mode
Ambient Temperature 0 ~ 40°C(Full load)  40 ~ 60°C(Derating)
Mechanical Speccifications Mounting Wall Mount
Inverter Dimensions (L*W*H) 388*415*200mm 488*415*200mm 588*415*200mm 706*415*212mm
Inverter Weight (Solar Chg) KG 21 +2.5 22 +2.5 23 +2.5 27 +2.5 38 +2.5 48 +2.5 49 +2.5 60 +2.5 66 +2.5 70 +2.5 83+2.5
Shipping Dimensions (L*W*H) 550*520*310mm 650*520*310mm 750*520*310mm 900*540*410mm
Shipping Weight (Solar Chg)KG 23 +2.5 24 +2.5 25 +2.5 29 +2.5 40 +2.5 50 +2.5 51 +2.5 62 +2.5 68 +2.5 72 +2.5 95+2.5
Display Status LEDs / Status LEDs+LCD
Standard Warranty 1 Year

 

Note: Specifications subject to change without notice.1235777266_409 1235785292_111 1213468608_552 1213500579_9811213500583_383