MPPT Solar Charge & Discharge Controller
MPPT Solar Charge & Discharge Controller | |||
Rated Voltage | 12/24Vdc | 24Vdc | 48Vdc |
Rated charge current (include load current) | 40Amp or 60Amp | 40Amp | 40Amp |
Load current | 10Amp | ||
Input voltage range | 1W5/30-70Vdc | 30-100Vdc | 60-100Vdc |
Max. PV open circuit array voltage | 45/70Vdc | 100Vdc | 100Vdc |
Overload protection ( DC load ) | 2.0 * Inom > 5s 1.5, Inom > 5s
1.25 * Inom temperature controlled |
||
Typical idle consumption | At idle<10Amp | ||
Charge specification | 12V model | 24V model | 48V model |
Bulk charge | 14.6Vdc (default) | 29.2Vdc (default) | 29.2Vdc (default) |
Floating charge | 13.4Vdc (default) | 26.8Vdc (default) | 53.6Vdc (default) |
Equalization charge | 14.0Vdc (default) | 28.0Vdc (default) | 56.0Vdc (default) |
Over charge disconnection | 14.8Vdc | 29.6Vdc | 59.2Vdc |
Over charge recovery | 13.6Vdc | 27.2Vdc | 54.427Vdc |
Over discharge disconnection | 10.8Vdc (default) | 21.6Vdc (default) | 43.2Vdc (default) |
Over discharge reconnection | 13.2Vdc | 24.6Vdc | 49.2Vdc |
Temperature compensation | -13.2mV/°C | -26.4mV/°C | -52.8mV/°C |
Lead acid battery settings | Adjustable | ||
Ni Cad battery settings | Adjustable | ||
Load control mode | 1-Low Voltage Reconnect ( LVR ): Adjustable 2. Low Voltage Disconnect ( LVD): Automatic disconnection
3. Reconnection: Includes warning flash before disconnect & reconnection |
||
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc | 48.0-56.0Vdc |
Low voltage disconnect | 10.5-12.5Vdc | 21.0-25.0Vdc | 42.0-50.0Vdc |
Ambient temperature | 0-40 °C (Full load) 40-60 °C( De-Rating ) | ||
Altitude | Operating 5000 m, Non-Operating 16000 m | ||
Protection class | IP21 | ||
Battery temperature sensor | BTS- Optional Remote battery temperature sensor for increased charging precision | ||
Terminal size (fine / single wire) | #8AWG |