Residential Lithium-ion Battery Energy Storage System
Residential Lithium-ion Battery Energy Storage System
Inverter Speficication :
Model | UPV 5048E |
Battery | |
Battery Type | Lead~acid or Lithium~ion |
Battery Voltage Range | 40~60V |
Max. Charge/Discharge Current | 100A |
Charging Curve | 3 Stages |
Charging Voltage | Depends On Battery Type (Schedule 1) |
Input DC(PV Side) | |
Recommended Max. PV Power | 3kW |
Rated Voltage | 60~200V |
Max. Input Voltage | 200V |
Start Up Voltage | 75V |
MPPT Voltage Range | 75~170V |
Max. Input Current | 60A |
No.Of MPPT Trackers No.Of Strings Per MPPT Tracker |
1 |
PV Module Utilization | ≥99.6% |
Output AC (Back Up) | |
Rated Output Power | 5000W |
Max. AC Output Power | 5500W |
Back Up Switch Time | <8ms |
Rated output voltage | 230V (Single Phase) |
Rated frequency | 50Hz |
Rated output current | 22.7A |
Input Voltage Waveform | Sine Wave |
THDv (@linear load) | 2% |
No load loss | <50W |
Output AC(Grid side) | |
Rated Output Power | 5000W |
Max. AC Output Power | 5500W |
Rated grid voltage | 230V(177~267V/90~267V) (Single Phase) |
Rated grid frequency | 50Hz/60Hz (47Hz~55Hz/57Hz ~65Hz) |
Rated output current | 22.7A |
Power Factor | >0.95 |
THDi | <5% |
Efficiency | |
Max. efficiency | 95% |
Protection | |
Anti~islanding Protection | Integrated |
PV String Input Reverse Polarity Protection | Integrated |
Insulation Resistor Detection | Integrated |
Output Over Current Protection | Integrated |
Output Over Voltage Protection | Integrated |
Overtemperature protection | Integrated |
Surge protection | Integrated |
General Data | |
Display | LED+LCD |
Communication | RS485/CAN |
Dimensions (W*H*D) | 415*488*200mm |
Weight | 16kg |
Installation Style | Rack/Wall Mounted |
Topology | Transformer Isolation |
Operating Temperature Range | ﹣20~60℃ (Derating Treatment ls Required IfThe Radiator ls Above 80℃) |
Humidity | 0%~95% Relative Humidity (No Condensation |
Cooling | Intelligent Air Cooling |
Protection Degree | IP20 |
Max. operation altitude | 2000m (>2000m Derating) |
Warranty | 1 Years |
*Schedule 1: Battery Type And Charging Voltage | ||
Battery Type | Boost/Vdc | Float/Vdc |
Gel USA | 56Vdc | 54.8Vdc |
AGM 1 | 56.4Vdc | 53.6Vdc |
LiFePO4_LF14 | 57.6Vdc | 54.4Vdc |
MnNiCo_N14 | 54.8Vdc | 54.8Vdc |
Custom | Set The Information According To The Specification Of The Battery |
Battery Sepficication :
Normal specification | ||
Model | LFPM48210H | |
Rated Voltage | 51.2V | |
Rated Capacity | 210Ah | |
Rated Energy | 10.75KWH | |
Cell Configuration | 16S2P | |
Battery Cell | 3.2V105AH 32PCS(EVE LF105) | |
Life cycles(80%DOD,25℃) | 6000 Cycles | |
Standard Charge | ||
Operation temperature range ©charging | 0~60℃ | |
Rated charge voltage | 56V | |
Max charge voltage | 56.8±0.4V | |
Overcharge protection | 58.4±0.4V | |
Allowed MAX charge current | 205A | |
Peak charge current | 210A | |
Rated charge current | 200A | |
Recommend charge current | <200A | |
Standard discharge | ||
Operation temperature range ©discharging | -35~60°C | |
Output Voltage Range | 43.2~56.8Vdc | |
Recommend Working Range | 46.4~56Vdc | |
Discharge Cut-off voltage | 43.2V | |
Allowed MAX discharge current | 205A | |
Peak discharge current | 210A | |
Rated discharge current | 200A | |
Recommend discharge current | <200A | |
Communication | ||
LCD Display | 2.8 inch color LCD | |
RS485/CAN | Matching with leading inverter brands | |
Expansion | Up to 16units in parallel(RS485 parallel communication) | |
RS232 | PC monitor | |
Dip SW | Additional setting | |
Storage and Transportation requirements | ||
Storage Temperature | Less than 1 month | -20~35°C |
Less than 6 month | -10-30°C | |
Storage Humidity | 45~75%RH | |
SOC | Storage | 60~75% SOC |
Transport | 45~55% SOC | |
Mechanical Characteristics | ||
Enclosure | IP54 | |
Dimension H*W*D | 890*490*175mm | |
Shipping H*W*D | 1000*670*400mm | |
N.W. | 100KG | |
G.W. | 110KG |
Write your message here and send it to us