4th Gen HP Mini Series  Inverter with Charger 600W/1000W/1500W
Low Frequency Pure Sine Wave Inverter & Charger

4th Gen HP Mini Series Inverter with Charger 600W/1000W/1500W

Short Description:

 

Features:

♦ Smart Remote Control

♦ Support Solar Panel with MPPT Function

♦ Designed to Operate under Harsh Environment

♦ DC Start & Automatic Self- Diagnostic Function

♦ Compatible with Both Linear & Non-Linear Load

♦ Easy to Install & Easy to Operate & Easy to Solve

♦ Low DC Voltage Supports Home & Office Appliances

♦ Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%

♦ High Efficiency Design & “Power Saving Mode” to Conserve Energy

♦ Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration

♦ 13 Vdc Battery Recover Point, Dedicated for Renewable Energy Systems

♦ 8 Pre Set Battery Type Selector Plus De-sulphation for Totally Flat Batteries

♦ 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger

♦ 8 ms Typical Transfer Time Between Utility & Battery, Guarantees Power Continuity

♦ 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator

    product detail

    HP mini Series Pure Sine Wave Inverter Charger1

    HP Mini Series Pure Sine Wave Inverter &Charger

    ♦ Ultra Low THD, Typically 7% Under Full Linear Load

    ♦ MPPT Solar Charger Controller Available

    ♦ Remote Control Available

    ♦ Battery Temperature Sensing For Increased Charging Precision

    ♦ Auto Gen Start Function For Off Grid System With Generator As Backup Power

    Feature of HP Series Inverter & MPPT & Charger

    Features

    ♦ Smart Remote Control

    ♦ Support Solar Panel with MPPT Function

    ♦ Designed to Operate under Harsh Environment

    ♦ DC Start & Automatic Self- Diagnostic Function

    ♦ Compatible with Both Linear & Non-Linear Load

    ♦ Easy to Install & Easy to Operate & Easy to Solve

    ♦ Low DC Voltage Supports Home & Office Appliances

    ♦ Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%

    ♦ High Efficiency Design & “Power Saving Mode” to Conserve Energy

    ♦ Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration

    ♦ 13 Vdc Battery Recover Point, Dedicated for Renewable Energy Systems

    ♦ 8 Pre Set Battery Type Selector Plus De-sulphation for Totally Flat Batteries

    ♦ 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger

    ♦ 8 ms Typical Transfer Time Between Utility & Battery, Guarantees Power Continuity

    ♦ 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator

    Slide to the left for full table
    HP MINI Pure Sine Wave Inverter/Charger
    Electrical Specification
    Inverter Output Power Rating 600W 1000W
    Continuous Output Power 600W 1000W
    Surge Rating(20s) 1800W 3000W
    Output Waveform PureSine Wave/Same as input(Bypass mode)
    Nominal Efficiency 80%(peak)
    Line Mode Efficiency <95%
    Power Factor 0.9-1.0
    Nominal Output Voltage RMS 120Vac or 230Vac
    Output Voltage Regulation ±10%RMS
    Output Frequency 50/60Hz±0.3Hz
    Short Circuit Protection Yes, Current Limit Function(Full after 1sec)
    Typical transfer time 10ms(Max)
    THD Typically<3%,Max 10% under full liner load
    DC Input Nominal Input Voltage 12.0Vdc
    Minimum Start Voltage 10.0Vdc
    Low Battery Alarm 10.5Vdc/11.0Vdc
    Low Battery Trip 10.0Vdc/10.5Vdc
    High Voltage Alarm & Fault 16.0Vdc
    High DC Input Recovery 15.5Vdc
    Low Battery Voltage Recover 13.0Vdc
    Idle Consumption-Search Mode <25W when Power Saver on
    AC Charger Input Voltage Range Narrow:100-135VAC/194-243Vac
    Wide:90-135VAC/164-243Vac
    Input Frequency Range Narrow:47-55±0.3Hz for 50Hz,57-65±0.3Hz for 60Hz
    Wide:43±0.3Hz plus for 50Hz/60Hz
    Output Voltage Depends on battery type
    Charger Breaker Rating(120Vac) 7A 10A
    Max Charge Rate 20A to 25A+/-5A,depending on models
    Over Charge Protection Shutdown 15.7V for 12Vdc
    Battery type Fsat Vdc Float Vdc
    Gel U.S.A 14 13.7
    A,G.M 1 14.1 13.4
    A.G.M 2 14.6 13.7
    Sealed Lead Acid 14.4 13.6
    Gel Euro 14.4 13.8
    Open Lead Acid 14.8 13.3
    Calcium 15.1 18.6
    De-sulphation 15.5 for 4hrs
    Remote Control Yes. Optional
    Bypass & Protection Input Voltage Waveform Sine wave(Grid or Generator)
    Nominal Voltage 120Vac 230Vac
    Low Voltage Trip 80V/90V±4% 184V/154V±4%
    Low Voltage re engage 90V/100V±4% 194V/164V±4%
    High Voltege Trip 140V±4% 253V±4%
    High Voltage re engage 135V±4% 243V±4%
    Max Input AC Voltage 150VAC 270VAC
    Nominal Input Frequency 50Hz or 60Hz(Auto detect)
    Low Freq Trip Narrow:47±0.3Hz for 50Hz,57±0.3Hz for 60Hz
    Wide:40±0.3Hz for 50Hz/60Hz
    Low Freq re engage Narrow:48±0.3Hz for 50Hz,58±0.3Hz for 60Hz
    Wide:45±0.3Hz for 50Hz/60Hz
    High Freq Trip Narrow:55±0.3Hz for 50Hz,65±0.3Hz for 60Hz
    Wide: No up limit for 50Hz/60Hz
    High Freq re engage Narrow:54±0.3Hz for 50Hz,64±0.3Hz for 60Hz
    Wide: No up limit for 50Hz/60Hz
    Mechanical Specification Inverter Dimensions(L*W*H) 325*173*135mm/12.8*6.8*5.3〞 362*173*135mm/14.3*6.8*5.3〞
    Inverter Weight 7.5KG/16.5Ib 11KG/24.3Ib
    Shipping Dimensions(L*W*H) 425*230*205mm/16.7*9*8〞 475*230*205mm/18.7*9*8〞
    Shipping Weight 8.5KG/18.7Ib 12KG/26.5Ib
    Display Status LED
    Standard Warranty 1 Year

    HP mini Series Pure Sine Wave Inverter Charger 2

    HP mini Series Pure Sine Wave Inverter Charger 3

    On the rear panel of inverter, there are 5 DIP switches which enable users to customize the performance of the device.

    Switch NO Switch Function Position: 0 Position: 1
    SW1 Low Battery Trip Volt 10.0VDCFor Deep-Cycle Battery 10.5VDCFor Starting Battery
    *2 for24Vdc,*for48Vdc
    SW2 AC Input Range AC Source For Utility Mode For Generator Mode
    230Vac HV 184-253Vac 140-270Vac
    120Vac LV 100-135Vac 90-135Vac
    SW3 Power Saver Auto Setting Night Charger Function Detect Load Per 3Secs
    SW4 O/P Frequency Setting 50Hz 60Hz
    SW5 Solar/AC Priority Setting Utility Priority Battery Priority

    Low Battery Trip Volt:

    The Low Battery Trip Volt is set at 10.0VDC by default. It can be customized to 10.5VDC

    AC Input Range:

    There are different acceptable AC input ranges for different kinds of loads. It can be customizedfrom 184-253VAC to 140-270VAC.

    Load Sensing Cycle:

    The inverter is factory defaulted to detect load for 250ms in every 30 seconds. This cycle can becustomized to 3 seconds thru the SW3 on DIP switch.

    Frequency adjust:

    The frequency of the inverter is arranged by the Sw4.The factory default configuration for 220/230/240VAC inverter is 50Hz,and 60Hz for 100/110/120VACinverter. While the output freq can be easily changed once a qualified freq is applied to the inverter.

    Solar / AC Priority Setting:

    Our inverter is designed AC priority by default. This means, when AC input is present, the battery will be charged first, and the inverter will transfer the input AC to power the load. The AC Priority and Battery Priority switch is available upon request. When you choose battery priority, the inverter will inverting from battery despite the AC input.HP mini Series Pure Sine Wave Inverter Charger 6